• Reconstituted calibrator stable for 21 days @ 2–8°C
• For use with Ref. No. 0590 and Ref. No. 0710
0595-003
1 x 3 mL
• Calibrators referenced to National Glycohemoglobin Standardization Program (NGSP)
• Four (4) level calibrator set with % HbA1c values
• For user with Ref. No. 0360-040
0365-401
4 x 0.5 mL
• Reported with instrument specific values
• Reconstituted calibrator stable up to 7 days @ 2–8°C, total and direct bilirubin are stable for 5 days @ 2-8°C
0550-605
6 x 5 mL
2460-605
6 x 5 mL
0355-201
2 x 0.5 mL
0357-201
2 x 1 mL
1225-205
2 x 5 mL
1235-305
3 x 5 mL
0330-302
3 x 2 mL
3065-601
6 x 1.5 mL
503000
6 x 1.5 mL
303000
2 x 3 mL
1175-305
3 x 5 mL
other leading reagent manufacturers
• Over 60 different constituents including
therapeutic drugs
• Reported with instrument specific values
G427-86
6 x 5 mL
other leading reagent manufacturers
• Over 60 different constituents including
therapeutic drugs
• Reported with instrument specific values
G428-86
6 x 5 mL
2465-605
6 x 5 mL
• Ready-to-use liquid reagent
• Linear from 70 to 120 mEq/L
• Read @ 500 nm
• Standard included
0210-250
R: 1 x 250 mL
STD: 1 x 3 mL
(100 mEq/L)
• Ready-to-use liquid reagent
• Endpoint reaction
• Linear to 4.3 mEq/L
• Read @ 520 nm
• Standard included
0130-430
R: 4 x 30 mL
STD: 1 x 3 mL
(2 mEq/L)
• Ready-to-use liquid reagent
• Linear to 20 mg/dL
• Read @ 340 nm
• Standard included
0830-125
R: 1 x 250 mL
STD: 1 x 3 mL
(10 mg/dL)
• Ready-to-use liquid reagents
• Working reagent stable up to
60 days @ 2–8°C
• 5 minute incubation @ 15–30°C
• Excellent correlation with flame
photometer and ISE
• Use serum, plasma, or urine
• Linear to 10 mmol/L
• Read @ 580 nm
• Standard included
0160-050
50 Test
STD: 1 x 3 mL
(4 mmol/L)
• Ready-to-use liquid reagents
• Colorimetric assay correlates
well with flame photometer
• Linear to 160 mmol/L
• Read @ 420 nm
• Standard included
0140-050
50 Test
STD: 1 x 6 mL
(140 mmol/L)
• Ready-to-use liquid reagents
• Working reagent stable up to
4 weeks @ 2-8°C
• Linear to 800 U/L
• Read @ 405 nm
2900-430
R1: 4 x 25 mL
R2: 4 x 5 mL
R2: 4 x 20 mL
• Ready-to-use liquid reagents
• Working reagent stable up to
4 weeks @ 2-8°C
• Linear to 600 U/L
• Read @ 340 nm
2930-430
R1: 4 x 25 mL
R2: 4 x 5 mL
R2: 4 x 20 mL
• Ready-to-use liquid reagent
• Use serum, plasma, or urine specimen
• Linear to 2000 U/L
• Read @ 405 nm
2970-430
R: 4 x 30 mL
• Ready-to-use liquid reagents
• Working reagent stable up to
4 weeks @ 2–8°C
• Linear to 600 U/L
• Read @ 340 nm
2920-430
R1: 4 x 25 mL
R2: 4 x 5 mL
R2: 4 x 20 mL
• NAC activated
• Ready-to-use liquid reagents
• Working reagent stable up to 3 weeks @ 2–8°C
• Linear from 1 to 1200 U/L
• Read @ 340 nm
2910-430
R1: 4 x 24 mL
R2: 4 x 6 mL
• Ready-to-use liquid reagents
• Working reagent stable up to
4 weeks @ 2–8°C
• Linear to 300 U/L
• Read @ 405 nm
2960-430
R1: 4 x 25 mL
R2: 4 x 5 mL
R2: 4 x 20 mL
• Ready-to-use liquid reagents
• Working reagent stable up to
2 weeks @ 2–8°C
• Linear to 800 U/L
• Read @ 340 nm
2940-430
R1: 4 x 25 mL
R2: 4 x 5 mL
R2: 4 x 20 mL
• Ready-to-use liquid reagent
• With Lipid Clearing Factor
• Use for Total and HDL Cholesterol assays
• Linear to 750 mg/dL
• Read @ 500 nm
• Standard included
1010-430
R: 4 x 30 mL
STD: 1 x 3 mL
(200 mg/dL)
STD: 1 x 3 mL
(200 mg/dL)
• Ready-to-use liquid reagent
• Stable @ 2–30°C
• Used with Enzymatic Cholesterol Test Set (Ref. No. 1010)
• Standard included
0599-020
R: 400 Test (1 x 20 mL)
STD: 1 x 3 mL
(50 mg/dL)
• Ready-to-use liquid reagents
• No sample pretreatment
• Linear to 150 mg/dL
• Read @ 600 nm
• Calibrator available separately (Ref. No. 0595-003)
0590-040
R1: 1 x 30 mL
R2: 1 x 10 mL
R2: 2 x 10 mL
R2: 1 x 125 mL
• Ready-to-use liquid reagents
• No sample pretreatment
• Linear to 520 mg/dL
• Read @ 600 nm
• Calibrator available separately
(Ref. No. 0595-003)
0710-080
R1: 2 x 30 mL
R2: 2 x 10 mL
Methodology
• Ready-to-use liquid reagent
• With Lipid Clearing Factor
• 5 minute incubation @ 37°C or 10 minutes @ 15–30°C
• Linear to 1000 mg/dL
• Read @ 500 nm
• Standard included
2200-430
R: 4 x 30 mL
STD: 1 x 2 mL
(200 mg/dL)
STD: 1 x 2 mL
(200 mg/dL)
Methodology
• Ready-to-use liquid reagents
• With Lipid Clearing Factor
• Working reagent stable up to 6 weeks @ 2-8°C
• 5 minute incubation @ 37°C or10 minutes @ 15–30°C
• Linear to 1000 mg/dL
• Read @ 500 nm
• Standard included
2100-430
R1: 4 x 30 mL
R2: 1 x 1.8 mL
STD: 1 x 2 mL
(200 mg/dL)
R2: 1 x 5.2 mL
STD: 1 x 2 mL
(200 mg/dL)
R2: 1 x 10 mL
• Enzymatic ß-Hydroxybutyrate reaction
• Ready-to-use liquid reagents
• Use serum or plasma
• Linear up to 4.5 mmol/L
• Read @ 505 nm
2440-058
R1: 1 x 50 mL
R2: 1 x 8.5 mL
STD: 1 x 3 mL
(1 mmol/L)
• Ready-to-use liquid reagents
• Working reagent stable up to 2 weeks @ 2–8°C
• Linear to 175 U/L
• Read @ 340 nm
2980-430
R1: 4 x 24 mL
R2: 4 x 6 mL
• Reconstituted reagent stable up to 5 days @ 2–8°C
• Linear to 175 U/L
• Read @ 340 nm
0980-103
R: 9 x 3.5 mL
• Single channel assay; does not require performing a Total Hemoglobin Test
• Liquid stable reagents
• For use with 2 reagent dispensing analyzers
• Linear from 2% to 16% HbA1c
0360-040
R1: 1 x 30 mL
R2(a): 1 x 9.5 mL
R2(b): 1 x 0.5 mL
R3(Lysing): 1 x 125 mL
• HbA1c reportable
• Aldimine elimination prevents falsely elevated results
• Easy to use — just mix, separate, and measure
• Separation in only 5 minutes
• HbA1, Linear from 4 – 20%
• HbA1c, Linear from 2.6 –16%
• Read @ 415 nm
• Standard included
0350-060
60 Test
STD: 1 x 1 mL
• Minimizes pipette errors
• Standard included
P350-020
20 Test
STD: 1 x 1 mL
STD: 1 x 1 mL
• Ready-to-use liquid reagent
• Use cerebrospinal fluid (CSF) or urine
• Linear to 150 mg/dL
• Read @ 600 nm
• Standard included
0345-212
R: 1 x 250 mL
STD: 1 x 3 mL
(100 mg/dL)
2450-604
6 x 4 mL
1012-030
30 mL
0600-030
30 mL
0325-006
6 x 15 mL
1072-030
30 mL
2103-030
30 mL
1022-030
30 mL
1044-030
30 mL
• Ready-to-use liquid reagent
• Linear to 7 g/dL
• Read @ 550 nm
• Standard included
0285-500
R: 2 x 250 mL
STD: 1 x 3 mL (6 g/dL)
• Use serum or plasma
• Ready-to-use liquid reagents
• For use with 2 reagent dispensing
analyzers
• Linear from 0.1 - 10 mg/dL
• Read @ 550 nm
• Multi-calibrator available separately
(Ref. No. 0550-605)
0235-450
R1: 3 x 120 mL
R2: 1 x 90 mL
Bilirubin (Ref. No. 0240-080)
0245-250
R: 1 x 250 mL
Oxidant: 1 x 15 mL
• Use serum or plasma
• Ready-to-use liquid reagents
• For use with 2 reagent dispensing
analyzers
• Linear from 0.07 - 30 mg/dL
• Read @ 540 nm
• Multi-calibrator available separately
(Ref. No. 0550-605)
0230-450
R1: 3 x 120 mL
R2: 1 x 90 mL
• Liquid reagents allow easy preparation
of working reagent
• Linear to 20 mg/dL
• Read @ 540 nm
• Calibrator included
0240-080
R: 1 x 250 mL
Oxidant: 1 x 15 mL
Calibrator: 1 x 6 mL
(10 mg/dL)
• Liquid reagents allow easy preparation
of working reagent
• Both total and direct reagents
• Read @ 540 nm
• Calibrator included
0260-200
R1: 1 x 100 mL
R2: 1 x 100 mL
Oxidant: 1 x 15 mL
Calibrator: 1 x 6 mL
(10 mg/dL)
• Ready-to-use liquid reagent
• Fast 1 minute incubation
• Linear to 15 mg/dL
• Read @ 650 nm
• Standard included
0155-225
R: 2 x 250 mL
STD: 1 x 3 mL
(10 mg/dL)
• Ready-to-use liquid reagents
• Working reagent stable for
14 days @ 2–8°C
• Linear to 15 mg/dL
• Read @ 550 nm
• Standard included
0150-250
R1: 1 x 125 mL
R2: 1 x 125 mL
STD: 1 x 3 mL
(10 mg/dL)
• No interference from Bilirubin, Ascorbic Acid or BUN
• Use serum or urine
• Ready-to-use liquid reagents
• For use with 2 reagent dispensing analyzers
• Linear to 30 mg/dL
• Read @ 550 nm
• Standard included
0430-120
R1: 3 x 30 mL
R2: 1 x 30 mL
STD: 1 x 5 mL
(5 mg/dL)
R2: 1 x 125 mL
STD: 1 x 5 mL
(5 mg/dL)
• Use serum or urine
• Ready-to-use liquid reagents
• Linear to 20 mg/dL
• Read @ 510 nm
• Standard included
0420-500
R1: 1 x 250 mL
R2: 1 x 250 mL
STD: 1 x 5 mL
(5 mg/dL)
• Use serum, plasma, or urine
• Ready-to-use liquid reagents
• Working reagent stable up to 90 days
• Linear to 500 mg/dL
• Read @ 340 nm
• Standard included
1060-500
R1: 4 x 105 mL
R2: 1 x 80 mL
STD: 1 x 3 mL
(100 mg/dL)
• Use serum, plasma, or CSF
• Ready-to-use liquid reagent
• 5 minute incubation @ 37°C
• Linear to 400 mg/dL
• Read @ 500 nm
• Standard included
1070-125
R: 1 x 250 mL
STD: 1 x 3 mL
(100 mg/dL)
STD: 1 x 3 mL
(100 mg/dL)
• Ready-to-use liquid reagents
• Fast 10 minute incubation @ 37°C
• Linear to 1000 μg/dL
• Read @ 560 nm
• Standard included
0370-110
R: 1 x 15 mL
Buffer 1: 1 x 125 mL
Buffer 2: 1 x 125 mL
STD: 1 x 30 mL
(500 μg/dL)
• Ready-to-use liquid reagent
• Linear to 10 g/dL
• Read @ 550 nm
• Standard included
0250-500
R: 2 x 250 mL
STD: 1 x 3 mL
(10 g/dL)
• Ready-to-use liquid reagents
• Working reagent stable up to
4 weeks @ 2–8°C
• Linear to 140 mg/dL
• Read @ 340 nm
• Standard included
2020-430
R1: 4 x 25 mL
R2: 4 x 5 mL
STD: 1 x 3 mL
(30 mg/dL)
R2: 4 x 20 mL
STD: 1 x 3 mL
(30 mg/dL)
• 5 minute incubation @ 37°C
• Linear to 100 mg/dL
• Read @ 600 nm
• Standard included
2050-450
R1: 2 x 50 mL
R2: 2 x 50 mL
STD: 1 x 3 mL
(30 mg/dL)
• Ready-to-use liquid reagents
• Linear to 80 mg/dL
• Read @ 520 nm
• Standards included
0580-250
250 Test
STD 1: 1 x 3 mL
(25 mg/dL)
STD 2: 1 x 3 mL
(50 mg/dL)
STD 3: 1 x 3 mL
(75 mg/dL)
• Ready-to-use liquid reagent
• With Lipid Clearing Factor
• 5 minute incubation @ 37°C or 15 minutes @ 15–30°C
• Linear to 20 mg/dL
• Read @ 520 nm
• Standard included
1045-430
R: 4 x 30 mL
STD: 1 x 3 mL
(8 mg/dL)
STD: 1 x 3 mL
(8 mg/dL)
• Ready-to-use liquid reagents
• Linear to 300 mg/L
• Read @ 615 nm
• Standard included
2400-060
R1: 1 x 40 mL
R2: 1 x 20 mL
STD: 1 x 3 mL
(300 mg/L)
• Ready-to-use liquid reagents
• Linear to 1000 mg/L
• Read @ 340 nm
• Standard included
2410-051
R1: 1 x 50 mL
R2: 1 x 1 mL
STD: 1 x 3 mL
(300 mg/L)