Stanbio Laboratory

Product Overview

REAGENTS WITH LIPID CLEARING FACTOR (LCF)
In some cases, patient specimens with increased lipid concentrations appear turbid. This turbidity can cause problems in the performance of photometric assays and can be avoided by employing pre-treatment steps. Such steps, however, are time-consuming and prone to error. Stanbio has developed a mixture of special additives, collectively called LCF, to eliminate these pre-treatment steps. LCF is integrated in the respective assay reagent and begins working immediately in the incubation phase of the test procedure. Clearing is achieved within minutes (e.g. up to 2000 mg/dL triglycerides, equivalent to 22.8 mmol/L, is cleared within 2-3 minutes at room temperature). Stanbio LCF assays, therefore, do not require additional pre-treatment steps allowing for easily obtained correct results.

Ordering Information

Cholesterol LiquiColor® Test (Enzymatic)
Modified Trinder Methodology
• Ready-to-use liquid reagent
• With Lipid Clearing Factor
• Use for Total and HDL Cholesterol assays
• Linear to 750 mg/dL
• Read @ 500 nm
• Standard included
Ref No.
1010-430
Contents
R: 4 x 30 mL
STD: 1 x 3 mL
(200 mg/dL)
1010-225
R: 2 x 250 mL
STD: 1 x 3 mL
(200 mg/dL)
1011-001
R: 1 x 1000 mL
Cholesterol, HDL Test,Precipitating Reagent
Mg/Dextran Sulfate Methodology
• Ready-to-use liquid reagent
• Stable @ 2–30°C
• Used with Enzymatic Cholesterol Test Set (Ref. No. 1010)
• Standard included
Ref No.
0599-020
Contents
R: 400 Test (1 x 20 mL)
STD: 1 x 3 mL
(50 mg/dL)
Cholesterol, HDL, Direct LiquiColor® Test (Enzymatic)
Homogeneous Method for Direct HDL Measurement
• Ready-to-use liquid reagents
• No sample pretreatment
• Linear to 150 mg/dL
• Read @ 600 nm
• Calibrator available separately (Ref. No. 0595-003)
Ref No.
0590-040
Contents
R1: 1 x 30 mL
R2: 1 x 10 mL
0590-080
R1: 2 x 30 mL
R2: 2 x 10 mL
0590-500
R1: 3 x 125 mL
R2: 1 x 125 mL
Cholesterol, LDL, Direct LiquiColor® Test (Enzymatic)
Homogeneous Method for Direct LDL Measurement
• Ready-to-use liquid reagents
• No sample pretreatment
• Linear to 520 mg/dL
• Read @ 600 nm
• Calibrator available separately
(Ref. No. 0595-003)
Ref No.
0710-080
Contents
R1: 2 x 30 mL
R2: 2 x 10 mL
Triglycerides LiquiColor® Test (Mono)
Glycerylphosphate Oxidase (GPO)
Methodology
• Ready-to-use liquid reagent
• With Lipid Clearing Factor
• 5 minute incubation @ 37°C or 10 minutes @ 15–30°C
• Linear to 1000 mg/dL
• Read @ 500 nm
• Standard included
Ref No.
2200-430
Contents
R: 4 x 30 mL
STD: 1 x 2 mL
(200 mg/dL)
2200-225
R: 2 x 250 mL
STD: 1 x 2 mL
(200 mg/dL)
Triglycerides LiquiColor® Test (Enzymatic)
Glycerylphosphate Oxidase (GPO)
Methodology
• Ready-to-use liquid reagents
• With Lipid Clearing Factor
• Working reagent stable up to 6 weeks @ 2-8°C
• 5 minute incubation @ 37°C or10 minutes @ 15–30°C
• Linear to 1000 mg/dL
• Read @ 500 nm
• Standard included
Ref No.
2100-430
Contents
R1: 4 x 30 mL
R2: 1 x 1.8 mL
STD: 1 x 2 mL
(200 mg/dL)
2100-225
R1: 2 x 250 mL
R2: 1 x 5.2 mL
STD: 1 x 2 mL
(200 mg/dL)
2100-001
R1: 1 x 1000 mL
R2: 1 x 10 mL

Contact Us

Stanbio Laboratory

1261 North Main Street
Boerne, TX 78006
Map and Directions
Contact Stanbio Laboratory

Customer Service

Toll-Free in the USA: 1-800-531-5535
Main: (830) 249-0772
Fax: (830) 249-0851
Contact Customer Service

Sales Department

1-866-STANBIO or 1-866-782-6246
Contact Sales Department

Technical Support

1-800-531-5535
Request Product Assistance
Contact Technical Support

Careers

1-830-249-0772
Contact Human Resources