Product Overview
Stanbio Laboratory continues to offer the broadest range of liquid-stable clinical chemistry reagents available worldwide. Our line of LiquiColor® and Liqui-UV® reagents are designed for maximum stability, ease-of-use and are optimized for today’s chemistry analyzers.
Ordering Information
• Ready-to-use liquid reagent
• Linear to 7 g/dL
• Read @ 550 nm
• Standard included
0285-500
R: 2 x 250 mL
STD: 1 x 3 mL (6 g/dL)
• Use serum or plasma
• Ready-to-use liquid reagents
• For use with 2 reagent dispensing
analyzers
• Linear from 0.1 - 10 mg/dL
• Read @ 550 nm
• Multi-calibrator available separately
(Ref. No. 0550-605)
0235-450
R1: 3 x 120 mL
R2: 1 x 90 mL
Bilirubin (Ref. No. 0240-080)
0245-250
R: 1 x 250 mL
Oxidant: 1 x 15 mL
• Use serum or plasma
• Ready-to-use liquid reagents
• For use with 2 reagent dispensing
analyzers
• Linear from 0.07 - 30 mg/dL
• Read @ 540 nm
• Multi-calibrator available separately
(Ref. No. 0550-605)
0230-450
R1: 3 x 120 mL
R2: 1 x 90 mL
• Liquid reagents allow easy preparation
of working reagent
• Linear to 20 mg/dL
• Read @ 540 nm
• Calibrator included
0240-080
R: 1 x 250 mL
Oxidant: 1 x 15 mL
Calibrator: 1 x 6 mL
(10 mg/dL)
• Liquid reagents allow easy preparation
of working reagent
• Both total and direct reagents
• Read @ 540 nm
• Calibrator included
0260-200
R1: 1 x 100 mL
R2: 1 x 100 mL
Oxidant: 1 x 15 mL
Calibrator: 1 x 6 mL
(10 mg/dL)
• Ready-to-use liquid reagent
• Fast 1 minute incubation
• Linear to 15 mg/dL
• Read @ 650 nm
• Standard included
0155-225
R: 2 x 250 mL
STD: 1 x 3 mL
(10 mg/dL)
• Ready-to-use liquid reagents
• Working reagent stable for
14 days @ 2–8°C
• Linear to 15 mg/dL
• Read @ 550 nm
• Standard included
0150-250
R1: 1 x 125 mL
R2: 1 x 125 mL
STD: 1 x 3 mL
(10 mg/dL)
• No interference from Bilirubin, Ascorbic Acid or BUN
• Use serum or urine
• Ready-to-use liquid reagents
• For use with 2 reagent dispensing analyzers
• Linear to 30 mg/dL
• Read @ 550 nm
• Standard included
0430-120
R1: 3 x 30 mL
R2: 1 x 30 mL
STD: 1 x 5 mL
(5 mg/dL)
R2: 1 x 125 mL
STD: 1 x 5 mL
(5 mg/dL)
• Use serum or urine
• Ready-to-use liquid reagents
• Linear to 20 mg/dL
• Read @ 510 nm
• Standard included
0420-500
R1: 1 x 250 mL
R2: 1 x 250 mL
STD: 1 x 5 mL
(5 mg/dL)
• Use serum, plasma, or urine
• Ready-to-use liquid reagents
• Working reagent stable up to 90 days
• Linear to 500 mg/dL
• Read @ 340 nm
• Standard included
1060-500
R1: 4 x 105 mL
R2: 1 x 80 mL
STD: 1 x 3 mL
(100 mg/dL)
• Use serum, plasma, or CSF
• Ready-to-use liquid reagent
• 5 minute incubation @ 37°C
• Linear to 400 mg/dL
• Read @ 500 nm
• Standard included
1070-125
R: 1 x 250 mL
STD: 1 x 3 mL
(100 mg/dL)
STD: 1 x 3 mL
(100 mg/dL)
• Ready-to-use liquid reagents
• Fast 10 minute incubation @ 37°C
• Linear to 1000 μg/dL
• Read @ 560 nm
• Standard included
0370-110
R: 1 x 15 mL
Buffer 1: 1 x 125 mL
Buffer 2: 1 x 125 mL
STD: 1 x 30 mL
(500 μg/dL)
• Ready-to-use liquid reagent
• Linear to 10 g/dL
• Read @ 550 nm
• Standard included
0250-500
R: 2 x 250 mL
STD: 1 x 3 mL
(10 g/dL)
• Ready-to-use liquid reagents
• Working reagent stable up to
4 weeks @ 2–8°C
• Linear to 140 mg/dL
• Read @ 340 nm
• Standard included
2020-430
R1: 4 x 25 mL
R2: 4 x 5 mL
STD: 1 x 3 mL
(30 mg/dL)
R2: 4 x 20 mL
STD: 1 x 3 mL
(30 mg/dL)
• 5 minute incubation @ 37°C
• Linear to 100 mg/dL
• Read @ 600 nm
• Standard included
2050-450
R1: 2 x 50 mL
R2: 2 x 50 mL
STD: 1 x 3 mL
(30 mg/dL)
• Ready-to-use liquid reagents
• Linear to 80 mg/dL
• Read @ 520 nm
• Standards included
0580-250
250 Test
STD 1: 1 x 3 mL
(25 mg/dL)
STD 2: 1 x 3 mL
(50 mg/dL)
STD 3: 1 x 3 mL
(75 mg/dL)
• Ready-to-use liquid reagent
• With Lipid Clearing Factor
• 5 minute incubation @ 37°C or 15 minutes @ 15–30°C
• Linear to 20 mg/dL
• Read @ 520 nm
• Standard included
1045-430
R: 4 x 30 mL
STD: 1 x 3 mL
(8 mg/dL)
STD: 1 x 3 mL
(8 mg/dL)